Filtered Search Results
Search results for "Restriction Enzymes"
Thermo Scientific™ Buffer Set for Restriction Enzymes
Ensure the optimum reaction conditions for each restriction enzyme with this five buffer system.
Thermo Scientific™ Dilution Buffer for Restriction Enzymes
Optimize applications that require diluted enzymes with this dilution buffer.
Thermo Scientific™ FastDigest BglII
Cut at A^GATCT sites with FastDigest™ BglII restriction enzyme, which performs best at 37°C in 5-15 minutes using universal FastDigest Buffer.
Sensitive to Heat Inactivation | No |
---|---|
Product Type | Restriction Enzyme |
Enzyme | Bgl II |
Methylation Sensitivity | Not Dam Methylation-Sensitive,Not Dcm Methylation-Sensitive,Not CpG Methylation-Sensitive |
Research Category | Traditional Cloning |
Compatible Buffer | 10X FastDigest Buffer/FastDigest Green Buffer |
Overhang | 5' protruding ends |
Type IIS RE | No |
Optimal Reaction Temperature | 37°C |
Product Line | FastDigest™ |
Thermo Scientific™ Eco32I (EcoRV), HC (50 U/μL)
The Eco32I (EcoRV) restriction enzyme recognizes GAT^ATC sites and cuts best at 37°C in R buffer (Isoschizomers: EcoRV).
Thermo Scientific™ FastDigest HindIII
The FastDigest HindIII restriction enzyme recognizes A^AGCTT sites and cuts best at 37°C in 5-15 minutes using universal FastDigest Buffer.
Sensitive to Heat Inactivation | Yes |
---|---|
Product Type | Restriction Enzyme |
Enzyme | Hind III |
Methylation Sensitivity | Not Dam Methylation-Sensitive,Not Dcm Methylation-Sensitive,Not CpG Methylation-Sensitive |
Research Category | Traditional Cloning |
Compatible Buffer | 10X FastDigest Buffer/FastDigest Green Buffer |
Overhang | 5' protruding ends |
Type IIS RE | No |
Optimal Reaction Temperature | 37°C |
Inactivation Temperature | 80°C |
Product Line | FastDigest™ |
Thermo Scientific™ SmaI (10 U/μL)
Cut at CCC^GGG sites with SmaI restriction enzyme, which performs best at 30°C in Tango buffer (Isoschizomers: TspMI, XmaCI, XmaI).
Concentration | 10 U/μL |
---|
Thermo Scientific™ FastDigest Eco47I
Cut at G^GWCC sites with Thermo Scientific™ FastDigest™ AvaII (Eco47I), which performs best at 37°C in 5-15 minutes using universal FastDigest Buffer.
Thermo Scientific™ BglII (10 U/μL)
Cut at A^GATCT sites with BglII restriction enzyme, which performs best at 37°C in O buffer.
Concentration | 10 U/μL |
---|
Thermo Scientific™ FastDigest BcuI
FastDigest SpeI (BcuI) restriction enzyme recognizes A^CTAGT sites and cuts best at 37°C in 5-15 minutes using universal FastDigest Buffer (Isoschizomers: AhlI).
Sensitive to Heat Inactivation | No |
---|---|
Product Type | Restriction Enzyme |
Enzyme | Bcu I |
Methylation Sensitivity | Not Dam Methylation-Sensitive,Not Dcm Methylation-Sensitive,Not CpG Methylation-Sensitive |
Research Category | Traditional Cloning |
Compatible Buffer | 10X FastDigest Buffer/FastDigest Green Buffer |
Overhang | 5' protruding ends |
Type IIS RE | No |
Optimal Reaction Temperature | 37°C |
Product Line | FastDigest™ |
Thermo Scientific™ FastDigest NheI
Thermo Scientific FastDigest NheI restriction enzyme recognizes G^CTAGC site and cuts best at 37°C in 5–15 minutes using universal FastDigest Buffer.
Sensitive to Heat Inactivation | Yes |
---|---|
Product Type | Restriction Enzyme |
Enzyme | Nhe I |
Methylation Sensitivity | CpG Methylation-Sensitive,Not Dam Methylation-Sensitive,Not Dcm Methylation-Sensitive |
Research Category | Traditional Cloning |
Compatible Buffer | 10X FastDigest Buffer/FastDigest Green Buffer |
Overhang | 5' protruding ends |
Type IIS RE | No |
Optimal Reaction Temperature | 37°C |
Inactivation Temperature | 65°C |
Product Line | FastDigest™ |
Thermo Scientific™ FastDigest PagI
Cut at T^CATGA sites with Thermo Scientific™ FastDigest™ BspHI (PagI), which performs best at 37°C in 5-15 minutes using universal FastDigest Buffer (Isoschizomers: CciI, RcaI).
Thermo Scientific™ FastDigest SacI
The FastDigest SacI restriction enzyme recognizes GAGCT^C sites and cuts best at 37°C in 5-15 minutes using universal FastDigest Buffer (Isoschizomers: Eco53kI, EcoICRI, Psp124BI, SstI).
Sensitive to Heat Inactivation | Yes |
---|---|
Product Type | Restriction Enzyme |
Enzyme | SacI |
Methylation Sensitivity | Not Dam Methylation-Sensitive,Not Dcm Methylation-Sensitive,Not CpG Methylation-Sensitive |
Research Category | Traditional Cloning |
Compatible Buffer | 10X FastDigest Buffer/FastDigest Green Buffer |
Overhang | 3' protruding ends |
Type IIS RE | No |
Optimal Reaction Temperature | 37°C |
Inactivation Temperature | 65°C |
Product Line | FastDigest™ |
Thermo Scientific™ FastDigest BshTI
Cut at A^CCGGT sites with Thermo Scientific™ FastDigest™ AgeI (BshTI), which performs best at 37°C in 5-15 minutes using universal FastDigest Buffer.
Thermo Scientific™ FastDigest Esp3I (IIs class)
Cut at CGTCTC(1/5)^ sites with Thermo Scientific™ FastDigest™ BsmBI (Esp3I), which peforms best at 37°C in 5-15 minutes using universal FastDigest Buffer.
Thermo Scientific™ FastDigest PaeI
Perform single-, double- or multiple DNA digestion within 5-15 minutes with this advanced line of restriction enzymes, 100% active in one universal buffer.